IEC61131-PLC standard 100% simulator PLC programming support modbus TCP RTU/ASCII 24V input motion control plc basics with CE

FOB Reference Price:Get Latest Price
$80.00 - $800.00 / Pieces | 1 Piece/Pieces (Min. Order)
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Fujian, China (Mainland)
Brand Name:
Sanch
Model Number:
Cloud Platform PLC
Output Power:
MAX 25VA
Output Type:
Dual
Size:
Depend
Weight:
1.5KG
Input Voltage:
100-240VAC/24VDC
Output Voltage:
100-240VAC/24VDC
Type:
AC/DC supply
Output Frequency:
50-60hz
Output Current:
Load
Features:
with ethernet+ and cloud programming
Temperature/Humidity:
working:0~+55℃ Storage temperature:-25~+70℃ Humidity: 5~95%RH,
Instantaneous surge:
MAX 20A 1.5ms @220VAC
Interference Immunity:
AC EFT:±2500V Surge:±2500V
5V voltage output(for CPU):
5V,-2%~+2%,1.2A
power protection:
DC 24V output over current
Insulation Type:
Transformer isolation or optoelectronic isolation,1500VAC/1 minute
Input Signal:
No voltage contact or NPN/PNP
Action driving:
ON>3.5mA OFF<1.5mA
Maximum Input Current:
10mA
Supply Ability
Supply Ability:
100000 Piece/Pieces per Year
Packaging & Delivery
Packaging Details
The inverter in a plastic bag would be protected by two EPE buffers in a carton independently. And then each packed item would be stacked up on pallets if the quantity is large. ac motor speed cotnroller
Port
optional

Cloud Platform
Cloud is a cross-platform IOT cloud platform. It supports PC, iPad, Android, IOS and other terminals. You can visit on-site equipments from a thousand miles away, and realize the remote monitoring and maintaining for HMI and PLC. It supports remote programming,firmware upgrades,monitoring and diagnosis etc.
Cloud provides security mechanisms for communication. It is secured by the encryption mechanism of 128-bit SSL,which ensures the stable and safe data transfer. It also uses A-key and B-Key protection mechanism to enable secure remote access to the devices.

General Information

 

Sanch PLC keep IEC61131-PLC international standard programming language. At present, we use  LADDER GIAGRAM, INSTRUCTIONLIST and FUNCTION BLOCK DIAGRAM. 

 

Characters 

 

1. Simulator: built-in simulator which reaches 100% simulation

 

2. communication functions:

A.  Fivecommunication ports, including two on main frame and another three extensible

B.  The functions of these five ports is completely same. all can be main/sub station, can connect with net and support programe upload & download and monitor

C.  Different baud rat, different data types, different communication protocol in sub-station is supported at same 485 net

 

3. Analog proccesing 

A.  Support to use project directly

B.  Analog can visit AI AO resistor directly without needing any project

 

 

 

 

Power Supply Specification

 
Item AC Power Supply
Power Supply Voltage 100~240VAC
Power Supply Frequency 50~60Hz
Power Consumption 25VA MAX
4Instantaneous Surge 20A 1.5ms MAX @220VAC
Power Loss Time20ms or less @220VAC
Fuse2A, 250VAC
5V Output Voltage (for CPU)5V, -2%~+2%, 1.2A MAX
24V Output Voltage (for output and extension)24V, -15%~+15%, 500mA MAX
24V Output Voltage (for input and peripheral)24V, -15%~+15%, 300mA MAX
Insulation TypeTransformer isolation or optoelectronic isolation,1500VAC/1 minute
Power ProtectionDC24V output over current

 

 

 

 

Digital Input (DI) / Output (DO)Specification
Input(DI)

 Digital Input (DI)
Input SignalNo voltage contact or NPN/PNP
Action drivingON>3.5mA OFF<1.5mA
Input ImpedanceInput Impedance≈4.3KΩ
Maximum Input
Current
10mA
Reaction Time6.4ms DEFAULT, can be configured to
0.8~51.2ms
Insulation TypeOptoelectronic isolation for each channel
Input IndicationLED's lighting indicates ON, no light indicates OFF
Power supplyMPU internal power supply:DC power supply
(SINK or SOURCE) 5.3mA@24VDC

 

 

Output(DO)
ItemOutput point type : Relay - ROutput point type :Transistor - T
Maximu
m load
Resistive Load2A/1 point, 8A/4 points COM0.5A/1 point, 2A/4 points COM
Inductive Load50VA5W/DC24V
Lamp load100W12W/DC24V
Minimum Load10mA2mA
Voltage SpecificationBelow 250VAC, 30VDC30VDC
Drive CapabilityMaximum contact capacity:
5A/250VAC
1A MAX, 10 seconds
Reaction TimeOff-on 10ms,On-off 5msOff→On 10us,On→Off 120us
Insulation TypeMechanical isolationOptoelectronic isolation for each
channel
Output IndicationLED's lighting indicates ON, no light indicates OFF
Power SupplyMPU internal 24VDC power supply

 

MPU Terminal Wiring Diagram

 

Programming Cable Wiring

 

 

 

 

 

You May Like